Used Transformer 2500 KVA, 20/400 V
1. Product Description
The 2500 KVA transformer, with voltages of 20 kV and 400 V, is an essential power management device in large-scale industrial and commercial applications. This used transformer is designed to convert high medium voltage (MV) voltages to low low voltage (LV) voltages, making it suitable for a wide range of applications.
2. Technical Specifications
- Brand and Model: (Not specified in detail, therefore generalized for transformers with these characteristics)
- Year of Construction: (Year not specified, but recent construction is assumed if in good condition)
- Power: 2500 KVA
- Primary Voltage (MT): 20 kV
- Secondary Voltage (LV): 400 V
- Insulation Type: (Specific insulation details not provided, but can typically be mineral oil or resin)
3. Components and Structure
-
Nucleus:
- Material: Made of silicon steel fins to reduce hysteresis and eddy current losses.
- Construction: Sandwich design with overlapping slats to improve efficiency and reduce noise.
-
Coils:
- Material: Copper or aluminum windings, covered with high-resistance insulation.
- Configuration: Primary and secondary coils wound on separate cores to reduce losses and improve efficiency.
-
Tank and Insulation:
- Insulation Type: Can be mineral oil or resin. Mineral oil is common in older transformers and provides cooling and insulation. Resin is more modern and offers better protection against environmental contamination.
-
Cooling System:
- Mineral Oil: The cooling system uses oil to dissipate the heat generated during operation.
- Resin: For recent models, cooling can occur through solidified resin, which offers excellent protection against humidity.
4. Dimensions and Weight
- Dimensions: 2500 KVA transformers are generally of significant size, typically 3 x 3 x 3.5 metres, but exact dimensions can vary.
- Weight: Approximately 5,000 - 6,000 kg, depending on construction and materials used.
5. Mechanical Characteristics
- Efficiency: High operating efficiency with low losses thanks to advanced construction and high-quality materials.
- Reliability: Rugged and designed to operate in demanding industrial and commercial environments.
- Protection: High quality insulation to ensure the safety and durability of the transformer.
6. Procedure for Use
-
Installation:
- Positioning: Install the transformer on a stable and protected base. Ensure there is sufficient space for ventilation and maintenance.
- Connection: Connect the high voltage (20 kV) and low voltage (400 V) terminals according to the manufacturer's specifications and make sure all connections are correct.
-
Power On and Monitoring:
- Power On: Follow specific startup procedures and monitor operating parameters such as voltage and current.
- Monitoring: Regularly check temperature and operating conditions to ensure the transformer is functioning properly.
-
Maintenance:
- Regular Inspections: Check the condition of the transformer and verify the integrity of the components.
- Cleaning: Keep the surrounding area clean and free of debris to avoid operational problems.
7. Matching Accessories
- Monitoring Devices: Temperature sensors, measuring instruments to monitor performance, and alert systems for abnormal conditions.
- Additional Cooling Systems: If necessary, install fans or other cooling systems for high-load environments.
8. Mathematical Formulas for Optimal Usage Parameters
9. Materials and Applications
- Workable Materials: Suitable for resistive and inductive loads in industrial and commercial environments.
- Applications: Industrial plants, large commercial buildings, power transformation and distribution stations.
10. Maintenance and Verification of Used Goods
-
Maintenance:
- Periodic Checks: Perform regular checks and insulation tests to ensure optimal operation.
- Cleaning: Remove dust and debris buildup to keep the transformer in good condition.
-
Used Goods Check:
- General Condition: Inspect for signs of wear and physical damage. Check the quality of the insulation and connections.
- Operation Test: Make sure the transformer operates within specifications and without any abnormalities.
11. Areas of Use
- Industrial: For large manufacturing plants and industrial operations.
- Commercial: To power commercial buildings and distribution centers.
- Energy and Infrastructure: Used in transformer stations for large-scale power distribution.
12. Advantages of Buying Used
- Lower Cost: Greater savings compared to new transformers.
- Reliability: When properly maintained, used transformers can deliver excellent performance and a long life.
- Immediate Availability: Faster availability than purchasing new units.
Conclusion
The 2500 KVA used transformer, with voltages of 20/400 V, is a powerful and reliable solution for your energy needs. With its sturdy construction and high-quality materials, it offers a long life and excellent performance. Purchasing a used transformer can be a cost-effective choice, with the guarantee of solid and reliable performance.
Transport included.
Additional services are offered upon request for a fee:
- Inspection
- Testing
- 1 year warranty