CCT smoke boiler - 3,000 kg/h capacity, 12 bar, gas - used, reliable and performing
If you are looking for a used boiler, but of high quality, the CCT smoke boiler , built in 1994 , is an opportunity that you cannot miss. With a capacity of 3,000 kg/h and a pressure of 12 bar , this machine is designed to guarantee high performance in the industrial field. Reliable, robust and with a system of preheating of the air that improves energy efficiency, the CCT boiler is one of the ideal solutions for companies that want to optimize costs without sacrificing quality.
Technical characteristics of the CCT boiler
- Brand and model : CCT, smoking tubes boiler, built in 1994.
- Steam production capacity : 3,000 kg/h. This makes the boiler suitable for a wide range of industrial applications that require a continuous and reliable steam generation.
- Operating pressure : 12 bar. An ideal level for industrial applications where high pressure steam is necessary to power production processes.
- Type of boiler : with smoke tubes, a traditional configuration that allows high thermal efficiency and long duration.
- Fuel : It works in gas , an economic and easily available energy source.
- Year of construction : 1994. Despite the age, the boiler is still fully functional, with a solid construction that allows it to be very resistant over time.
Main components of the CCT smoking boiler
The CCT boiler consists of numerous components designed to optimize steam production and its efficiency:
- Smoking tubes : smoking pipes are the heart of the heating system. The heat produced by the combustion of gas is transferred to water through these tubes, generating steam.
- Hearth : the combustion area where the heat generation process takes place. The burner system is optimized for efficient combustion.
- Air preheat : an advanced system that allows you to heat the combustion air before it enters the hearth, improving thermal performance and reducing consumption.
- Steel structure : the boiler is built with resistant materials, suitable for supporting high pressure and temperatures, guaranteeing longevity and reliability.
Physical dimensions and specifications of the boiler
The CCT boiler has small but very powerful dimensions. The robust design and compact structure are designed to optimize space, while maintaining a high level of efficiency. Specific measures may vary depending on the configuration, but generally the boiler is positioned in a medium -sized band for this type of product.
How to use the CCT tubes boiler
The use of the CCT boiler is quite simple, but requires attention and care:
- Ignition : to start the boiler, connect the source of gas and activate the ignition system. The boiler will automatically begin to heat the water and produce steam.
- Steam production : when the boiler reaches the desired temperature and pressure (about 12 bar), the produced steam is ready to be used in industrial processes.
- Pressure monitoring : it is essential to keep the pressure and temperature under control through the control panel, to ensure safe and continuous production of steam.
- Shitting and cleaning : once the cycle is finished, turn off the boiler and clean the smoke pipes to avoid accumulations of residues that could compromise the performance.
Compatible accessories with the CCT boiler
Some accessories that can be added to the CCT boiler to improve their efficiency and safety include:
- Remote control systems to monitor the operation of the boiler at a distance, improving operational management.
- Filters and purifiers for the treatment of fumes and reduce the environmental impact.
- Steam accumulation tanks to ensure constant availability of steam even in moments of greatest request.
Maintenance of the CCT boiler
To maintain the CCT boiler in optimal conditions, it is essential to follow correct maintenance:
- Cleaning of smoking pipes : every now and then, smoking tubes must be cleaned to avoid incrustations that reduce thermal efficiency.
- Burner control : Maintenance of burners is important to ensure regular and safe combustion.
- Verification of the safety valve : the boiler must be equipped with safety valves to prevent situations of surcharge.
- Inspection of the Air Preheator : the air preheating must be periodically verified to make sure it works correctly.
Safety and Regulatory Compliance
The CCT boiler is built with materials resistant to high pressure and high temperatures, and although the CE certifications are not always indicated, it is essential to follow local regulations for installation and use. The machine must be used only after carrying out the necessary safety checks, especially as regards the permitted maximum pressure.
Sectors of use of the CCT boiler
The CCT boiler is ideal for a variety of industrial sectors that require steam:
- Chemical sector : for heating reactors and for the production of steam for chemical applications.
- Food industry : for the sterilization and thermal treatment of food products.
- Textile sector : for the treatment of fabrics and the production of steam for textile machinery.
- Carta industry : for the treatment of paper material during production.
Why buy a used boiler CCT
Buying a used CCT boiler represents an excellent savings opportunity, especially for those companies that want to reduce initial investment costs. The boiler, despite the age (1994), is still highly functional thanks to its solid construction and reliability. If purchased by an expert dealer, this used boiler can guarantee excellent performance, especially when it has been correctly maintained.
Conclusions
The CCT smoking tubes , with its capacity of 3,000 kg/h and a pressure of 12 bars , represents a quality industrial solution, capable of satisfying the steam production needs in numerous sectors. Thanks to the preheating air , the boiler is more efficient from an energy point of view. The purchase of a boiler used CCT offers excellent quality-price ratio, with a robust machine that can continue to work for many years, if correctly maintained. An opportunity not to be missed for those looking for a lasting and convenient product.